Function Outgoing Call

The function Outgoing Call starts the subsequent actions from the PLC. One connection per function is supported. This method works only if the configured type is a participant.

Warning: If the connected variable is true, a call will be started immediately upon application.

Note: This function uses a License SIP Participant. Therefore, always consider the limitations. The order of license allocation is not defined.

Note: Currently, an answered call cannot be terminated by Antcas Control.

Parameter Call

The variable that is listened to. As long as this is true, the connection will be maintained. The variable can be dragged from the structure into the field using Drag&Drop.

If the connection is rejected by the other party or the ringing ends, the variable will be reset to FALSE.

Output CONTEXT

Execute next command. This output is usually used with the function Dial.