eQ-3 MAX!

The interface connects a MAX! Cube in the local network of eQ-3 via TCP/IP.

Setting Up The Interface

The interface is first set up with the Windows or iOS app MAX!. You need to know the IP address of the MAX! Cube. The Scanner from Antcas Control can find this. The IP address should be permanently assigned by the DHCP server of the router.

Important: The MAX! Cube supports only a maximum of one simultaneous connection. Therefore, first set up the devices and then activate the gateway.

Tip: The software can be downloaded from the following link:
https://www.max-portal.elv.de/

The rooms and devices are later automatically imported into Antcas Control by the gateway. Therefore, choose meaningful names. The names can also be changed later without affecting the control from Antcas Control.

It is recommended to control the weekly program via the calendar of the visualization and remove it from the room thermostats.

Control And Functions

The value mode can take the following values:

Value Function
0 Automatic (Weekly Program)
1 Manual
2 Vacation
3 Boost

The value temp can take the following values:

Value Function
4.5 OFF (Always Off)
5..30 Temperature In 0.5 Steps
30.5 ON (Always On)

Duty Cycle

The interface has an automatic duty cycle limitation. That is, the more radio traffic there is, the longer it takes to send the telegrams. This is calculated as follows:

t[Seconds]=4+duty_cycle*3